Followers

Wednesday, December 18, 2013

Object Variable or With block variable not set error in FDM 11.1.2.2

Object Variable or With block variable not set error in FDM

Description: When configuring Hyperion FDM Load Blance Configuration, we did use correct user in General tab, we will get error in Authentication provider tab.

Load Balance Manager Configuration Screen:

Authentication Providers tab:


Solution: Start --> Run --> dcomcnfg 

Computers --> My Computer --> DCOM Config --> Right click on COMJNIBridge --> Properties


In properties tab, goto Identity tab then change username(windows user) which is used for FDM configuration.


Then try again Authentication Provider, 



                                                                                                                        Thanks,
                                                                                                                       Mady

Getting blank screen when try to install Offline planning from Workspace in 11.1.2.2


Getting blank screen when try to install Offline planning from Workspace in 11.1.2.2

When we are try to install Offline planning from Hyperion Workspace, it is giving blank screen.
Cause: OfflinePlanning.exe is not in proper location.

Blank screen:

Solution: Workspace expecting OfflinePlanning.exe file from the below location.
E:\Oracle\Middleware\EPMSystem11R1\common\epmstatic\wspace\OfflinePlanning\Client
(Note: In wspace folder, if OfflinePlanning\Client are not there, create it and paste OfflinePlanning.exe file in Client folder)


Thanks,
Mady